| | TYPE | CAPACITY | | YDSN- 2KC | 2 Kgf-cm | 0.196NM | | YDSN- 5KC | 5 Kgf-cm | 0.490NM | | YDSN- 10KC | 10 Kgf-cm | 0.980NM | | YDSN- 20KC | 20 Kgf-cm | 1.961NM | | YDSN- 50KC | 50 Kgf-cm | 4.903NM | | YDSN- 100KC | 100 Kgf-cm | 9.807NM | | YDSN- 200KC | 200 Kgf-cm | 19.61NM | | YDSN- 500KC | 500 Kgf-cm | 49.03NM | | YDSN- 1000KC | 1000 Kgf-cm | 98.07NM |
| Customer specific capacity range avaliable |
| | | |
|
| | SETech's Mode YDSN non-rotating socket wrench transducers are used to measure the fastening torque or the break away torque of bolts and nuts. This model is designed to fit a standard socket and a standard torque wrench. |
|
| |
| SPECIFICATIONS | Rated capacity | 2 Kgf-cm ~ 1000 Kgf-cm |
| | Temperature range compensated | -10℃~60℃ |
| | | Temperature range safe | -20℃~70℃ |
| | Temperature effect, on zero balance | 0.05%R.O/10℃ |
| | Temperature effect, on rated output | 0.1%Load/10℃ |
| | Excitation recommended | 10V DC |
| Terminal resistance input | 350±5Ω |
| | Terminal resistance output | 350±3Ω |
| | Insulation resisitance | 2000MΩ |
| |
|
|
|
|
| |
| DIMENSIONS | CAPACITY | socket SIZE | A | B | C | D
| ØE | F | G | M | H | K | L | | 2kgf-cm | 1/4" | 58 | 33 | 12 | 4 | 14 | 11 | 6.35 | 10 | 19.5 | 20 | 11 | | 5,10kgf-cm | 3/8" | 59.5 | 33 | 12 | 5.5 | 16.5 | 13 | 9.53 | 12 | 21 | 24 | 13 | | 20,50kgf-cm | 1/2" | 71 | 37 | 16 | 7 | 21 | 16 | 12.7 | 13.5 | 23 | 27 | 16 | | 100,200kgf-cm | 3/4" | 81 | 37 | 20 | 10 | 30 | 21 | 19.1 | 18 | 28 | 36 | 21 | | 500,1000kgf-cm | 1" | 98 | 39 | 27 | 14 | 41.5 | 29 | 25.4 | 24 | 33 | 48 | 28 |
|
|
|
| |
 |