簡單介紹

DSC數字化模塊 高速應變傳感器數字化模塊 RS232/485/CAN等總線可選 OEM PCB安裝,方便集成于設備內部 高精度,高穩定性(1/200000) 18bit 內建9點線性修正 支持外接溫度傳感器補償溫度 支持遠程SHUNT 500次/秒傳輸速度


數字化模塊  的詳細介紹

DSCH High Stability 

DSC數字化模塊
高速應變傳感器數字化模塊
RS232/485/CAN等總線可選
OEM PCB安裝,方便集成于設備內部
高精度,高穩定性(1/200000) 18bit
內建9點線性修正
支持外接溫度傳感器補償溫度
支持遠程SHUNT
500次/秒傳輸速度
Description Min  Typical Max Units
Bridge Excitation 4.5 5 5.25  VDC
Sensor Impedance up to 18v Supply 320 350  5,000  Ohms**
Sensor Impedance up to 12v Supply 120 350  5,000  Ohms**
Bridge Sensitivity -3   +3  mV/V
Offset Temperature Stability   ppm/C
Gain Temperature Stability   ppm/C
Offset Stability with Time   0.002 0.008  %FR
Gain Stability with Time     30  ppm of FR/1st Year
Non Linearity   0.0005  0.0025  %FR
Internal Resolution 16 Million   16 Million    Counts/Divisions
Resolution @ 1Hz (Noise Stable) *   200,000    Counts/Divisions
Resolution @ 10Hz (Noise Stable) *   120,000   Counts/Divisions
Resolution @ 100Hz (Noise Stable) *   50,000   Counts/Divisions
Resolution @ 500Hz (Noise Stable) *   18,000    Counts/Divisions
Optional Temperature Measurement Resolution     0.1   ºC
Optional Temperature Measurement Accuracy    1   ºC
Notes: From original offset at any time. *Stability over 100 second period. **Subject to supply voltage. See Electrical Specification
Electrical
Power Supply Voltage 5.6 12  18  V dc
Power Supply Noise/Ripple     100  mV ac pk-pk
Power Supply Current (350R Bridge)   45  60  mA
Power @ 10V Supply (350R Bridge)   350    mW
Sensor Impedance up to 18v Supply  320  350  5,000  ohms
Sensor Impedance up to 12v Supply 120  350  5,000  ohms
Excitation System 4 wire   4 wire     
Environmental
Operating Temperature Range  -40   85  °C
Operating Temperature Range for OIML 6000d -10    55  °C
Storage Temperature -40    85  °C
Humidity   95  %RH on Condensing
Communications  
RS485 Data Rate 2,400   230k  Baud
CAN Bit Rate 10k    1M  Bits/Sec
Note: Update speeds are selectable to 1, 2, 5, 10, 20, 50, 60, 100, 200, 300, 500 Samples/Sec
Protocols

Available Now:
ASCII, MANTRABUS II, Modbus RTU, MantraCAN, Profibus - Contact Mantracourt for details.
Please Note: MantraCAN products will only work with Mantracourt software up to and including Windows Vista.

 DSCS Industrial Stability 

 Product  Min  Typical  Max  Units
Bridge Excitation 4.5 5.25   VDC
Bridge Impedance 320  350  5,000  Ohms
Sensor Impedance up to 18v Supply 320  350  5,000  Ohms**
Sensor Impedance up to 12v Supply 120  350  5,000  Ohms**
Bridge Sensitivity -3    -3  mV/V
Offset Temperature Stability   10  ppm/C
Gain Temperature Stability   30  50  ppm/C
Offset Stability with Time   0.0035  0.016  %FR „]
Gain Stability with Time     300  ppm of FR /1st Year
Non Linearity   0.0005  0.0025  % FR
Internal Resolution   16 Million    Counts/Divisions
Resolution @ 1Hz (Noise Stable) *   66,000   Counts/Divisions
Resolution @ 10Hz (Noise Stable) *   40,000    Counts/Divisions
Resolution @ 100Hz (Noise Stable) *   10,000   Counts/Divisions
Resolution @ 500Hz (Noise Stable) *   5,000   Counts/Divisions
Optional Temperature Measurement Resolution   0.1   °C
Optional Temperature Measurement Accuracy   1   °C
Notes: From original offset at any time. *Stability over 100 second period. **Subject to supply voltage. See Electrical Specification
 Electrical    
Power Supply Voltage 5.6 12 18  V dc
Power Supply Noise/Ripple     100  mV ac pk-pk
Power Supply Current (350R Bridge)   45  60  mA
Power @ 10V Supply (350R Bridge)   350    mW
Sensor Impedance up to 18v Supply 320  350  5,000  ohms
Sensor Impedance up to 12v Supply 120  350  5,000  ohms
Excitation System   4 wire     
 Environmental    
Operating temperature range -40    85  °C
Storage temperature -40   85  °C
Humidity   95  %RH Non Condensing
Communications    
RS485 Data Rate 2,400   230k  Baud
CAN Bit Rate 10k    1M  Bits/Sec
 Note: Update speeds are selectable to 1, 2, 5, 10, 20, 50, 60, 100, 200, 300, 500 Samples/Sec    
Protocols
Available Now:
ASCII, MANTRABUS II, Modbus RTU, MantraCAN. 
Please Note: MantraCAN products will only work with Mantracourt software up to and including Windows Vista.
The Benefits to the Transducer User/System Supplier    
Mantracourt has identified the following points which demonstrate how strain gauge transducers users will benefit.
1. Plug-in-and-go-sensor
No need for a separate instrument, DSC provides a direct output in engineering units from a standard Strain Gauge, - save cost and space.
2. Simple to use
The Strain Gauge manufacturer can supply the sensor pre-calibrated for system offset, gain, hysteresis and scale parameters.
3. Outstanding performance to cost ratio
19 bit (500,000 divisions) and 0.001% noise immunity ideal for high precision process weighing applications such as batching, at a fraction of the cost of many instrument solutions
4. Low cost of Strain Gauge ownership
Use with low cost 2 pair twisted cabling - reduce set-up costs.
• Digital storage of calibration details, means the system will not need regular re-calibration - save maintenance costs.
• In-service replacement of a faulty/damaged Strain Gauge is possible by simply down loading the stored calibration details to a new cell. Save maintenance time and cost by not having to empty a vessel and re-apply test weights.
5. Universal systems compatibility
Fieldbus connectivity ensures interoperability with existing/future process control equipment
6. Non-expert maintenance
Self diagnostics alerts user to common Strain Gauge faults such as over-range.
 Support Modules    
Instrument Explorer Software free PC software, RS232 - RS485 Convertor, DCell Evaluation Kits
Environmental    
CE Environmental Approvals European EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC